Filter Results By:

Products

Applications

Manufacturers

Showing results: 151 - 164 of 164 items found.

  • PXIe-4154, 2-Channel, 8 V, 3 A PXI Programmable Power Supply

    781155-01 - NI

    2-Channel, 8 V, ±3 A PXI Programmable Power Supply—The PXIe‑4154 is a specialized programmable power supply for battery simulation. It is designed to simulate a lithium‑ion battery cell’s transient speed, output resistance, and 2‑quadrant operation (source/sink). Critical to many RF and wireless applications, the simulator’s fast transient response time allows it to rapidly respond to changes in load current with minimal voltage dip, which makes the PXIe‑4154 ideal for powering devices under test (DUTs) such as RF power amplifiers, cellular handsets, and a variety of other mobile devices. To model the behavior of a battery more accurately, you can use the onboard programmable output resistance to simulate a battery’s internal resistance. For quiescent and standby current measurements, the PXIe‑4154 features integrated current measurement.

  • High-Voltage Power Amplifier / Piezo Driver

    Model 2205 - TREK, INC.

    The Trek Model 2205 is a member of Trek’s 2200-series of high-voltage 40 W amplifiers that offesr high performance at an attractive price. It incorporates DC stability, wide bandwidth, well regulated and controlled AC output signals, full four-quadrant class AB all-solid-state output stages, DC offset adjustment with front panel metering, and autorecovery shutdown to protect the output from being overpowered. The instrument also stage sinks or sources current into reactive or resistive loads throughout the output voltage range which makes it ideal to achieve the accurate output response and high slew rates demanded by reactive loads.

  • High-Voltage Power Amplifier / Piezo Driver

    Model 2220 - TREK, INC.

    Trek’s Model 2220 is one of several models within our 2200-series of high-voltage 40 W amplifiers. Provided at an attractive price and offering high performance, the unit incorporates DC stability, wide bandwidth and well regulated/controlled AC output signals. It also features full four-quadrant class AB all-solid-state output stages, DC offset adjustment with front panel metering, and autorecovery shutdown to protect the output from being overpowered. The instrument stage sinks or sources current into reactive or resistive loads throughout the output voltage range making it ideal to achieve the accurate output response and high slew rates demanded by reactive loads.

  • High-Voltage Power Amplifier / Piezo Driver

    Model 2210 - TREK, INC.

    Trek’s Model 2210 is one of several models within our 2200-series of high-voltage 40 W amplifiers. Provided at an attractive price and offering high performance, the unit incorporates DC stability, wide bandwidth and well regulated/controlled AC output signals. It also features full four-quadrant class AB all-solid-state output stages, DC offset adjustment with front panel metering, and auto recovery shutdown to protect the output from being overpowered. The instrument stage sinks or sources current into reactive or resistive loads throughout the output voltage range making it ideal to achieve the accurate output response and high slew rates demanded by reactive loads.

  • Converter Of Electrical Quantities

    Metra Blansko a.s.

    The converters are intended for the conversion of electrical quantities DC signal which is either in form of the DC voltage, or the DC forced current. They can be used in connection with indicating pointer instruments, calibrated in units of the measured quantity, or with a recorder or, eventually with a digital instrument. Wide range of possibilities are provided by them, also as sensors for regulation and control porposes in the fields of industrial measurements and, last but not least, as needful components for aquisition of technological enviroment picture applied for evaluating and processing computer systems. The converters are designed for continuous operation. They are designed as independent, built in the plastic casing. Each converter comprises the input circuits for the galvanic separation of the proper measuring circuit and the output amplifier for the output signal conversion to the unified output.

  • LXI Low Thermal EMF Matrix 1-pole 14x33

    60-510-004 - Pickering Interfaces Ltd.

    The 60-510 is a high density 1-pole matrix module controlled via LXI. It has excellent thermal stability and substantially reduced thermal EMF figures when compared to a conventional switching matrix. Typical applications include signal routing in ATE, selecting thermocouple inputs, switching amplifier gain circuits and high accuracy DC micro-volt measurements. Ruthenium reed switches are used because of their good low level switching capability. They also have a very long life with excellent contact resistance stability, minimal wetting current and low thermal offset. The 60-510 is designed in accordance with the LXI Standard 1.4 and is supplied in a 2U high, full rack width case with 500mm depth.

  • Static Measurement

    Nex Flow Air Products Corp.

    electrofield meter is a small hand-held field strength meter with a digital display for measuring electrostatic charges in Volts. It perfectly combines easy operation with an accurate measuring technique. The Static Meter measures charges according to the field influence principle C: The influenced charges, caused by the electrical field, generate an alternating current proportional to the electrical field strength. The selective amplifier converts this value into the corresponding field strength or electrical potential – without withdrawing energy from the electric field over the averaged time.

  • [5kV AC] Hipot Tester, Rise/Fall-Time Control Function Equipped

    TOS5200 - Kikusui Electronics Corp.

    TOS5200 is designed for AC Hipot Test with 500 VA capacity and 200 mA short circuit current output capability. Equipped with the PWM amplifier, the TOS5200 can provide a stable & reliable output without being affected by ACpower line. Therefore, it is a perfect solution for electronic equipment or devices complied to IEC, EN, UL, VDE andJIS etc. requirement.As TOS5200 covers most of features of our upper class model for AC Hipot Test, it achieves thesuperb cost / performance ratio for those who need 200 VA or 500 VA capacity, or both. Also, as it equips the Interlockfunction together with other safety features, operator can carry out the test with higher current value in safe.

  • Measurement System for ESD Protection

    SampleProtect - Oxford Instruments plc

    The SampleProtect measurement system is ready to go, and comes complete with Oxford Instruments’ Cryofree bottom loading cryostat – the OptistatDry BLV, Zurich Instruments’ MFLI Lock-in Amplifier, a specially designed ESD break-out box and high quality measurement grade cables. The patent-pending puck style mounting from Oxford Instruments provides safe installation of your samples. The MFLI 500 kHz Lock-in Amplifier (capable of 500 kHz demodulation as standard) with MF-MD multi-demodulator capability brings the benefits of high performance signal processing at low and medium frequencies. The differential voltage and current inputs of the MFLI are optimised for low noise operation and the high oversampling rate ensures an even better signal to noise ratio. Zurich Instruments’ unique LabOne® control software provides a toolset including an integrated oscilloscope, a spectrum analyser, a plotter and a parameter sweeper.

  • 2-Quadrant Source/Measure Unit for Functional Test, 20 V, 1 A or 6 V, 3 A, 20 W

    N6782A - Keysight Technologies

    The Keysight N6782A is a source/measure unit (SMU) designed specifically for advanced functional testing of a device. The ability to modulate the output up to 100 kHz along with capability to source and sink current (2-quadrant operation) makes the N6782A a perfect fit for advanced functional test of a variety of devices such as DC/DC converters, power management units, power amplifiers, and power management ICs. The input stage of the DUT can be stimulated by the fast sourcing and waveform capabilities. While the output stage can be loaded down and measured with the electronic load capabilities, providing a total test solution.

  • IVTS In-Vehicle Test Set

    LXinstruments GmbH

    The in-vehicle test set was developed to successively measure several active RF amplifiers installed in the vehicle as well as different antenna structures. It offers the possibility to connect 12 DUTs. The DUTs can be connected to an external spectrum analyser via a 1 to 12 RF multiplexer. Each DUT can be individually switched and supplied with an adjustable voltage via a bias-tee integrated in the system. The individual bias voltages and currents are recorded by the IVTS and can be called up on an interactive control panel or via Ethernet and SCPI commands. The complete system can be powered by rechargeable battery and can be operated either via Ethernet, fibre optics or WLAN.

  • Amplifier, Switch and Test Box

    CLIOQC Model V - Audiomatica

    The QCBOX Model 5 is a non-conventional unit designed to fulfil actual and future needs of an electro-acoustical analyzer like the CLIO system. It is USB linked to a PC and can be configured, with dedicated software controls, to assist frequency response and impedance measurements or to perform DC measurements. Using it for frequency response measurements acts as 50W power amplifier to drive the speaker or network under test while routing one-of-four inputs to the analyzer as well the current sensing output. The four inputs are able to provide a phantom power supply both for Audiomatica or general purpose microphones (0-24 V range, software controlled). Impedance measurements can be done either switching the D.U.T.’s load across the analyzer’s input or using a dedicated output, ISENSE, thus allowing impedance measurements in constant voltage mode as well voice coil current distortion analysis. An internal ADC measures the DC current into the voice coil. Thanks to an internal software controlled voltage generator the speaker can be driven with a superimposed DC voltage (±20V), allowing for measurements of large signal parameters. Two ADC converters with a ±2.5 V and ±5 V are available at inputs 3 and 4 to measure the displacement with a laser sensor or any other DC signal. A dedicated digital input handles an external foot pedal switch (or TTL signal) to be connected and triggers QC operations. A 6 bit output – 5 bit input TTL digital port is available to interface the QCBOX and driving software with external hardware (like turntables for example).The QCBOX Model 5 finds use both in laboratory for R&D applications and in production lines setups.

  • PXIe High-Speed Source/Measure Unit, 13 V, ± 1 A or 6 V, ± 3 A, 18 W

    M9111A - Keysight Technologies

    The M9111A is a 1-slot, 2-quadrant PXIe module that provides stable, glitch-free sourcing and sinking, and high accuracy measurements. It offers high-throughput and measurement quality for design validation and production test of RF power amplifiers. With industry-leading output stability under extreme, dynamic load conditions and unmatched transient performance to dramatically reduce voltage droop due to pulse loading, the M9111A SMU speeds test time. The high-speed M9111A can change its output voltage, stabilize that voltage, and accurately measure current from Amps down to micro-Amps all in less than 1 ms so that you can move on to the next test as quickly as possible.

  • Spectral Response SystemsQuantum Efficiency SystemsIPCE Measurement Systems

    Photo Emission Tech., Inc.

    QE system provides electronics and software designed for fully automated measurement of external quantum efficiency of solar cells. All systems include probes and a fixed plate sample stage for samples up to 150 mm x 150 mm. The main system components include: custom designed software, measurement electronics, and computer system (Windows 8 operating system). The measurement involves focusing monochromatic light to a spot on the device under test, then accurately measuring the photon flux and current from the test cell. The system utilizes a dual beam configuration with lock-in detection, providing an absolute accuracy of ±3%. The QE system uses a grating monochrometer with silicon/InGaAs/Ge detectors. The system includes automatic order sorting filters and two light sources for monochromatic illumination (a Xenon- arc lamp and a halogen lamp). A single lock-in amplifier is used to measure both the reference detector and test device. The main system comes with all the hardware needed to measure quantum efficiency, a fixed plate sample stage and probes.

Get Help